Used Vacuum Pumps›Pfeiffer›Other

Pfeiffer · Other
Pfeiffer WGK 1000 — rotary piston pump, large capacity
Original title: Pfeiffer Vacuum WGK 1000 Wälzkolbenpumpe Vakuumpumpe
📍 Germany
Suitability for 1 × FD440
Not verifiedItem type
Not confirmed
Technical
Cannot calculate
Condition
Not evidenced
Data
Family only
🔴 Check carefully
Large rotary piston pump; unsuitable for WAVE freeze dryers due to size and displacement.
Condition from photo
Exterior clean, mounted on wooden pallet with motor and piping. No visible oil leaks. Label legible. Internal wear cannot be assessed from photos.
Likely refurb / add-ons
- Oil change and filter service (~€100)
- Soft-starter or VFD retrofit (~€300–500)
- Exhaust filter replacement (~€80)
Watch out for
- WGK 1000 is a large industrial rotary piston pump (typical displacement ~1000 m³
- Pump class and displacement mismatch with WAVE vacuum source requirements.
- No ultimate vacuum specification provided; rotary piston pumps are designed for
WAVE AI estimate from photo + specs only — not a substitute for our physical pre-purchase check.
Specifications
- Type
- other
- Source
- eBay
- Listing #
- eBay #257315440399
- Last verified
- Jun 30, 2026
The Other family is recognised, but the exact variant is not supported. Model-specific performance and water-vapour figures from Other Pfeiffer are therefore withheld.
Price history— Pfeiffer Other
Family: OtherExact model is not supported by the listing or type plate.
Median €1.110 · 903 cleaned observations · €374–€3.399
Type plate (AI reading)
- Exact model
- WGK 1000
- Manufacturer
- Arthur Pfeiffer Vakuumtechnik Wetzlar GmbH
- Company
- Ein Unternehmen der BALZERS-Gruppe
- Origin
- Made in Germany
Auto-extracted from one of the listing photos. Verify on the real unit before purchase.
What to look for on this family
Generic Pfeiffer vacuum pump — the exact model family was not detected automatically. Suitability remains unverified until the model or type plate is clear.
Traceable assessment
How each pump is assessed
AI helps read images and listing text. The final suitability result is calculated by a fixed engineering rule using evidenced values.
Method version: 5 August 2026
- 1
Identify the item
The title and photos are checked first to confirm that the listing is a complete vacuum pump — not an accessory, spare part or pump head only.
- 2
Establish evidence
The type plate and listing provide specific facts. Manufacturer values are used only for a confirmed model; family-level values stay clearly labelled.
- 3
Compare engineering data
Pumping speed, water-vapour capacity and ultimate pressure are compared with the selected WAVE machine and the chosen safety margins.
- 4
Assess condition separately
A photo or a seller saying “runs” does not replace a vacuum test. Unknown data remain unknown and never become an automatic green recommendation.