Busch · Other
Busch SD 1025 C — dry rotary vane, 240V 1ph
Original title: 240v Busch SD 1025 C Vacuum Pressure Oil-less Vane type Blower pump 1ph
📍 United Kingdom
Suitability for 1 × FD440
Not suitableItem type
Not confirmed
Technical
Cannot calculate
Condition
Not evidenced
Data
Family only
🔴 Check carefully
Dry pump unsuitable for WAVE; oil-sealed rotary vane required.
Condition from photo
Mounted on dark enclosure with visible piping and control box; overall cleanliness acceptable, no obvious leaks or damage visible.
Likely refurb / add-ons
- Soft-starter or VFD for 240V single-phase (€280–400)
- Exhaust filter replacement (€80–120)
Watch out for
- Dry rotary vane pump — WAVE freeze dryers require oil-sealed rotary vane or rota
- Single-phase 240V supply may require soft-starter or phase converter for laborat
- Model SD 1025 C is a blower/compressor variant, not a vacuum pump optimized for
WAVE AI estimate from photo + specs only — not a substitute for our physical pre-purchase check.
Specifications
- Type
- other
- Source
- eBay
- Listing #
- eBay #186212151553
- Last verified
- Aug 5, 2026
The Other family is recognised, but the exact variant is not supported. Model-specific performance and water-vapour figures from Other Busch are therefore withheld.
Price history— Busch Other
Family: OtherExact model is not supported by the listing or type plate.
Median €1.999 · 621 cleaned observations · €308–€7.200
What to look for on this family
Generic Busch vacuum pump — the exact model family was not detected automatically. Suitability remains unverified until the model or type plate is clear.
Traceable assessment
How each pump is assessed
AI helps read images and listing text. The final suitability result is calculated by a fixed engineering rule using evidenced values.
Method version: 5 August 2026
- 1
Identify the item
The title and photos are checked first to confirm that the listing is a complete vacuum pump — not an accessory, spare part or pump head only.
- 2
Establish evidence
The type plate and listing provide specific facts. Manufacturer values are used only for a confirmed model; family-level values stay clearly labelled.
- 3
Compare engineering data
Pumping speed, water-vapour capacity and ultimate pressure are compared with the selected WAVE machine and the chosen safety margins.
- 4
Assess condition separately
A photo or a seller saying “runs” does not replace a vacuum test. Unknown data remain unknown and never become an automatic green recommendation.