Used Vacuum Pumps›Pfeiffer›Other

Pfeiffer · Other
Pfeiffer SplitFlow 310 3P — rotary vane, 210 l/s
Original title: Pfeiffer SplitFlow 310 3P PM P04 299 Vakuumpumpe TC400 PMC01800A 15231802 Used
📍 Germany
Suitability for 1 × FD440
Not verifiedItem type
Not confirmed
Technical
Cannot calculate
Condition
Not evidenced
Data
Family only
🔴 Check carefully
High-capacity rotary vane; suitable for WAVE but requires full inspection and refurbishment.
Condition from photo
Exterior clean, mounted on frame with TC 400 controller. Oil level and internal wear cannot be assessed from photos. Nameplate legible.
Likely refurb / add-ons
- Oil change and filter service — €120
- Exhaust filter replacement — €80
- Bearing/seal inspection — €200–400
Watch out for
- No visible oil leaks, but internal condition unknown without disassembly.
- Controller (TC 400) is separate unit; verify compatibility and function before p
- High-capacity pump may exceed typical WAVE freeze-dryer requirements; confirm ch
WAVE AI estimate from photo + specs only — not a substitute for our physical pre-purchase check.
Specifications
- Type
- other
- Year
- 2001 (per nameplate)
- Source
- eBay
- Listing #
- eBay #267180085532
- Last verified
- Aug 5, 2026
The Other family is recognised, but the exact variant is not supported. Model-specific performance and water-vapour figures from Other Pfeiffer are therefore withheld.
Price history— Pfeiffer Other
Family: OtherExact model is not supported by the listing or type plate.
Median €1.110 · 903 cleaned observations · €374–€3.399
Type plate (AI reading)
- Exact model
- SplitFlow 310 3P
- Serial
- 15231802
- Year (plate)
- 2001
- Manufacturer Part No.
- PM P04 299
- Oil
- PM 063 265 -T
- Pumping speed S(N₂)
- 210 l/s
- Speed
- 60000 1/min
- Frequency
- 1000 Hz
- Weight
- 13 kg
- Origin
- Made in Germany
- Approvals
- CE, TÜV Rheinland, Safety approved USA-CAN
Auto-extracted from one of the listing photos. Verify on the real unit before purchase.
What to look for on this family
Generic Pfeiffer vacuum pump — the exact model family was not detected automatically. Suitability remains unverified until the model or type plate is clear.
Traceable assessment
How each pump is assessed
AI helps read images and listing text. The final suitability result is calculated by a fixed engineering rule using evidenced values.
Method version: 5 August 2026
- 1
Identify the item
The title and photos are checked first to confirm that the listing is a complete vacuum pump — not an accessory, spare part or pump head only.
- 2
Establish evidence
The type plate and listing provide specific facts. Manufacturer values are used only for a confirmed model; family-level values stay clearly labelled.
- 3
Compare engineering data
Pumping speed, water-vapour capacity and ultimate pressure are compared with the selected WAVE machine and the chosen safety margins.
- 4
Assess condition separately
A photo or a seller saying “runs” does not replace a vacuum test. Unknown data remain unknown and never become an automatic green recommendation.