Busch · Other
Busch KB 0040 D — rotary vane vacuum pump, 48 m³/h
Original title: Busch KB 0040 D Vakuumpumpe 1 Stück
📍 Poland
Suitability for 1 × FD440
Not verifiedItem type
Not confirmed
Technical
Cannot calculate
Condition
Not evidenced
Data
Family only
🟡 OK with refurb
Suitable for WAVE freeze dryers; typical refurbishment needed before deployment.
Condition from photo
Exterior shows moderate wear, dust accumulation, and minor corrosion on fasteners. Oil level and internal condition cannot be assessed from photos. Motor and drive appear intact.
Likely refurb / add-ons
- Oil change (Busch VM 068, 0.8 L) — €40
- Exhaust filter replacement — €80
- Soft-starter module (optional) — €280
Watch out for
- Age and service history unknown; no maintenance records visible
- Motor nameplate partially obscured; full electrical specs not confirmed
WAVE AI estimate from photo + specs only — not a substitute for our physical pre-purchase check.
Specifications
- Type
- other
- Source
- eBay
- Listing #
- eBay #177928145648
- Last verified
- Jul 23, 2026
The Other family is recognised, but the exact variant is not supported. Model-specific performance and water-vapour figures from Other Busch are therefore withheld.
Price history— Busch Other
Family: OtherExact model is not supported by the listing or type plate.
Median €1.999 · 621 cleaned observations · €308–€7.200
Type plate (AI reading)
- Exact model
- KB 0040 D I00
- Serial
- DEM122010212
- Manufacturer
- Busch Produktions GmbH, Schauinslandstrasse 1, D-79689 Maulb
- Pump Type
- Vacuum Pump
- Model
- KB 0040 D I00
- Absolute Pressure
- 3 hPa (mbar)
- Maximum Pumping Speed
- 48 m³/h
- Maximum Speed
- 3600 min⁻¹
- Oil Type
- Busch VM 068
- Oil Quantity
- 0.8 L
- Mass
- 29 kg
- Serial Number
- DEM122010212
- Origin
- Made in Germany
- Approvals
- CE
Auto-extracted from one of the listing photos. Verify on the real unit before purchase.
What to look for on this family
Generic Busch vacuum pump — the exact model family was not detected automatically. Suitability remains unverified until the model or type plate is clear.
Traceable assessment
How each pump is assessed
AI helps read images and listing text. The final suitability result is calculated by a fixed engineering rule using evidenced values.
Method version: 5 August 2026
- 1
Identify the item
The title and photos are checked first to confirm that the listing is a complete vacuum pump — not an accessory, spare part or pump head only.
- 2
Establish evidence
The type plate and listing provide specific facts. Manufacturer values are used only for a confirmed model; family-level values stay clearly labelled.
- 3
Compare engineering data
Pumping speed, water-vapour capacity and ultimate pressure are compared with the selected WAVE machine and the chosen safety margins.
- 4
Assess condition separately
A photo or a seller saying “runs” does not replace a vacuum test. Unknown data remain unknown and never become an automatic green recommendation.