Used Vacuum Pumps›Edwards›Other

Edwards · Other
Edwards E2M5 — rotary vane, 3.9 CFM
Original title: Edwards E2M5 Rotary Vacuum Pump (3.9cfm) with 115 volt Leeson 1/2 HP motor
Market median (sold): €1.951 from 48 sales in this family
Suitability for 1 × FD440
Not verifiedItem type
Complete pump
Technical
Cannot calculate
Condition
Not evidenced
Data
Family only
🟡 OK with refurb
Suitable for WAVE; typical refurb needed, motor included.
Condition from photo
Exterior clean, minor surface wear, oil level unclear, hoses present, motor appears functional.
Likely refurb / add-ons
- Oil change and filter service (€80–120)
- Exhaust filter replacement (€60–80)
- Soft-starter for motor (€280)
Watch out for
- Price significantly below median (€398 vs €1,951); verify pump history and inter
- Motor nameplate (Leeson) shows age; confirm electrical compatibility with WAVE c
WAVE AI estimate from photo + specs only — not a substitute for our physical pre-purchase check.
Specifications
- Type
- other
- Source
- eBay
- Listing #
- eBay #227236422960
- Availability checked
- Aug 7, 2026
The Other family is recognised, but the exact variant is not supported. Model-specific performance and water-vapour figures from Other Edwards are therefore withheld.
Price history— Edwards Other
Family: OtherExact model is not supported by the listing or type plate.
Median €1.860 · 1035 cleaned observations · €300–€12.887
Recent sales (Edwards Other)
- €18.611Aug 6, 2026iXH3050H Edwards NRY68N000 Dry Vacuum Pump IPN 500321166 New Surplus
- €732Aug 6, 2026Edwards E2M12 Dual-Stage Rotary Vane Vacuum Pump REBUILT 10 CFM KF25 240 V
- €669Aug 6, 2026Edwards E2M30 Dual Stage Rotary Vane Vacuum Pump P/N A374-15-903
- €8.896Aug 6, 2026Varian VHS-10 Diffusion Pump Vacuum Pump 4400W 380V 3Ph Edwards PV40MK / L5920-
- €698Aug 6, 2026Edwards E2M30 Dual Stage Rotary Vacuum Pump & Mist Filter Tested Working
- €1.116Aug 6, 2026Perfect Condition Edwards XDD1 Electric Diaphragm Vacuum Pump
- €697Aug 6, 2026Edwards E2M1.5 A37122902R Rotary Vane Vacuum Pump - TESTED ~0.0134 torr
- €6.509Aug 6, 2026Edwards Dry Scroll Pump - Unused in Box - TESTED with Warranty SEE VIDEO
- €2.279Aug 6, 2026EDWARDS Vacuum Pump E2M30 DUAL STAGE Pump REBUILT
- €2.558Aug 6, 2026Edwards iQDP 40 (MPN iQDP 40) Dry Vacuum Pump System with Control Panel
- €1.395Aug 6, 2026Edwards BOC XDS10 Dry Scroll Vacuum Pump A726-01-906 Oil-Free 6.5 CFM
- €4.842Aug 6, 2026iXL120 Edwards NRY294000 Dry Vacuum Pump IXL 120 LV/HV 1/4 OEM Refurbished
Source: eBay sold listings (Apify aggregation). Year inferred from listing title when present.
Type plate (AI reading)
- Exact model
- M4C17DC3A
- Serial
- 1725
- Detected in image
- 3 / 5
- Catalog No./Part No.
- 100019-01
- Model
- M4C17DC3A
- RPM
- 1725
- Horsepower
- 1/2
- Voltage
- 115 V
- Frequency
- 60 Hz
- Full Load Amperage
- 8.8 A
- Service Factor
- 1.15
- Efficiency
- 62
- Type
- CD
- Max. Ambient Temperature
- 40 °C
- Insulation Class
- B
- Duty
- CONT
- Thermal Protection
- LCFG65GA
- Design
- N
- Manufacturer
- Leeson Electric Corporation, Grafton, WI
- Origin
- Made in USA
Auto-extracted from one of the listing photos. Verify on the real unit before purchase.
What to look for on this family
Generic Edwards vacuum pump — the exact model family was not detected automatically. Suitability remains unverified until the model or type plate is clear.
Traceable assessment
How each pump is assessed
AI helps read images and listing text. The final suitability result is calculated by a fixed engineering rule using evidenced values.
Method version: 5 August 2026
- 1
Identify the item
The title and photos are checked first to confirm that the listing is a complete vacuum pump — not an accessory, spare part or pump head only.
- 2
Establish evidence
The type plate and listing provide specific facts. Manufacturer values are used only for a confirmed model; family-level values stay clearly labelled.
- 3
Compare engineering data
Pumping speed, water-vapour capacity and ultimate pressure are compared with the selected WAVE machine and the chosen safety margins.
- 4
Assess condition separately
A photo or a seller saying “runs” does not replace a vacuum test. Unknown data remain unknown and never become an automatic green recommendation.