Used Vacuum Pumps›Edwards›iH / EDM

Edwards · iH / EDM
Edwards iH 1800 — oil-sealed screw, 80 m³/h
Original title: iH 1800 Edwards NGAC73000XS Vakuum Trockenpumpe IH800 Hersteller generalüberholt
📍 USA
Suitability for 1 × FD440
Not verifiedItem type
Not confirmed
Technical
Cannot calculate
Condition
Not evidenced
Data
Type plate + model
🟡 OK with refurb
Suitable for IC550; typical refurb needed. Price well above recent market.
Condition from photo
Exterior clean, no visible oil leaks. Mounting frame intact. Hoses and electrical connections present. Label legible.
Likely refurb / add-ons
- Oil change and filter service (~€110)
- Soft-starter replacement (~€280)
- Bearing inspection and repack (~€150)
Watch out for
- Asking price €6,212 is 3–7× recent market median (€1,000); verify refurb scope a
- Screw pump requires more maintenance than rotary vane; confirm oil type and serv
WAVE AI estimate from photo + specs only — not a substitute for our physical pre-purchase check.
Specifications
- Type
- Dry screw
- Source
- eBay
- Listing #
- eBay #146696725301
- Last verified
- Aug 5, 2026
The iH / EDM family is recognised, but the exact variant is not supported. Model-specific performance and water-vapour figures from iH80 are therefore withheld.
Price history— Edwards iH / EDM
Family: iH / EDMExact model is not supported by the listing or type plate.
Median €4.793 · 96 cleaned observations · €1.848–€11.625
Recent sales (Edwards iH / EDM)
- €2.790May 8, 2026Edwards iH600 Dry Vacuum Pump - S/N: 563556678
- €846Mar 18, 2026Edwards D37291400 iL Series Vacuum Pump Electrics Module DP ITIM IH AC Surplus
Source: eBay sold listings (Apify aggregation). Year inferred from listing title when present.
Type plate (AI reading)
- Exact model
- NGAC73000XS
- Model
- NGAC73000XS
- Type
- iH 1800
- Pumping speed
- ~80 m³/h
- Ultimate vacuum
- ≤0.01 mbar
- Water-vapour tolerance
- ~5000 g/h
Auto-extracted from one of the listing photos. Verify on the real unit before purchase.
What to look for on this family
Industrial dry-screw / multi-stage. Oil-free, made for harsh process gases — handles water vapour without modification. Check the bearing temperature log if available.
Traceable assessment
How each pump is assessed
AI helps read images and listing text. The final suitability result is calculated by a fixed engineering rule using evidenced values.
Method version: 5 August 2026
- 1
Identify the item
The title and photos are checked first to confirm that the listing is a complete vacuum pump — not an accessory, spare part or pump head only.
- 2
Establish evidence
The type plate and listing provide specific facts. Manufacturer values are used only for a confirmed model; family-level values stay clearly labelled.
- 3
Compare engineering data
Pumping speed, water-vapour capacity and ultimate pressure are compared with the selected WAVE machine and the chosen safety margins.
- 4
Assess condition separately
A photo or a seller saying “runs” does not replace a vacuum test. Unknown data remain unknown and never become an automatic green recommendation.